Qualified SCSI HBA Cards Pro Tools Systems
for Windows XP
For maximum track count, use of a qualified SCSI HBA (Host Bus Adapter)
card is required with Pro Tools|HD systems.
Pro Tools 6.x & 7.x
The following card is officially qualified with Pro Tools 6.x & 7.x systems on
Windows XP.
Included With the Digidesign SCSI|128 Kit or Available as a Separate Purchase:
ATTO
EPCI-UL3D (Dual
Channel Ultra3 SCSI Host Bus Adapter - Model # EPCI-UL3D-000)
- Supports up to 192 tracks of playback and record with Pro Tools|HD
Accel Systems
- ATTO UL3D BIOS version 1.68 or higher required for the Digidesign SCSI|128/ATTO UL3D.
- For more information, see the following:
- This document, as well as the ATTO Utilities folder, is on the Pro Tools 6.9.x/7.x CDs. Also available from the Digidesign Technical Document Library
- The ATTO Utilities folder from the Pro Tools 6.9.x/7.x CDs is also available from the Storage Downloads Section
- Before upgrading ATTO driver and firmware, disconnect all
drives attached to the ATTO SCSI controller card
- Sync Rate set to "160DT (80)" (160 MB/sec at 80 MHz)*
- PCI Burst Rate set to 128*
- Selection Timeout: 16ms*
*Settings available via SCSI BIOS
Note: The 66MHz version of the ATTO EPCI-UL3D (model # EPCI-UL3D-066)
is not supported for use with Pro Tools systems, regardless of whether
your Pro Tools system is installed on a 33 MHz or 66 MHz PCI bus. The
66 MHz version is tuned for performance on a 66 MHz PCI bus. However,
when Pro Tools is installed in a 66 MHz PCI bus, it reduces the speed
of the PCI bus to 33 MHz. As a result, you will receive superior performance
with the 33 MHz UL3D, because it is tuned for a 33 MHz PCI bus.
Pro Tools 6.7 and Earlier Only — Not Tested with Pro Tools 6.9 and higher
Digidesign SCSI64 Kit/ATTO
EPCI-DC (Dual
Channel Ultra/WIDE SCSI Host Bus Adapter)
- Discontinued
- Supports up to 64 tracks of playback and record with Pro Tools|HD,
Pro Tools|HD Accel, and Pro Tools|24 MIX Systems
- ATTO ExpressPCI driver and firmware v1.68, available from www.attotech.com/software
- Before upgrading to ATTO 1.68 driver and firmware, disconnect all
drives attached to the ATTO SCSI controller card
- Sync Rate set to "20 (10)" (20 MB/sec at 10 MHz)*
- PCI Burst Rate set to 32*
*Settings available via SCSI BIOS
Built-In
Qualified with Pro Tools 6.4, 6.9.x, and 7.x with AVoption|V10 (and Avid Mojo with Pro Tools 6.9.x and 7.x)
- HP xw9300 (qualified with Pro Tools 6.9.x and 7.x only), HP xw8200 and HP xw8000: These computers have built-in
dual channel SCSI that have been qualified by Digidesign and a SCSI HBA